Thermal Energy Equipment and Systems:

  • Waste Heat Recovery Units (WHRU) for heating medium production
    • Water/glycol mixtures
    • Thermal oils
  • Once Through Steam Generators (OTSG) and Heat Recovery Steam Generators (HRSG)
    • Saturated Steam for Heating Purposes
    • Superheated Steam for Steam Turbine Operation
  • HRSG auxillary Systems
    • Make-up Water System incl. Integrated Fresh Water Maker System
    • Chemical Dosing System
    • Blow Down System
  • Feed Water/Deaerator System
  • Steam And Water Monitoring System
    • Online system
    • Manual Sampling System
  • HRSG/Steam Cycle Control Logic
  • Steel Support structures for WHRU/OTSG/HRSG and gas turbine ancillaries
  • New Projects
  • Retrofit/Modification Projects
      
 

 

 Studies and troubleshooting:
  • Front end and conceptual studies
  • System design, cost estimation, review and optimization
  • Offshore troubleshooting
  • CFD calculations (FLUENT)
  • FEM analysis of high temperature exposed exhaust systems
  • HYSYS calculations
  • Steam Cycle Balance of Plant Analysis
  • Commissioning and start-up




 WHRU alternatives

                 
                             








 

Type/
Design
Vertical
Hot Casing
Horizontal
Hot Casing
Vertical
Cold Casing
Horizontal
Cold Casing
Vertical circular
Hot Casing
Vertical circular
Cold Casing
Bundle:
Serpentines of
CC, low alloy, SS
finned tubes
Serpentines of
CC, low alloy, SS
finned tubes
Serpentines of
CC, low alloy, SS
finned tubes
Serpentines of
CC, low alloy, SS
finned tubes
Spirales of
CC, low alloy, SS
finned tubes
Spirales of
CC, low alloy, SS
finned tubes
Casing, ducting, stacks:
SS pickled and passivated or
low alloy steel
w/ surf protection/
Thermal spray
SS pickled and passivated or
low alloy steel
w/ surf protection/
Thermal spray
CS steel with surface protection
CS steel with surface protection
SS pickled and passivated or
low alloy steel
w/ surf protection/
Thermal spray
CS steel with surface protection
Insulation
Un-insulated or external insulation or personnel protection
Un-insulated or external insulation or personnel protection
Internal insulation w/studs & cladding
Internal insulation w/studs & cladding
Un-insulated or external insulation or personnel protection
Internal insulation w/studs & cladding
Exhaust damper
Louvres or Diverter
Louvres or Diverter
Louvres or Diverter
Louvres or Diverter
KT design rotational damper
KT design rotational damper
Damper actuator
Pneumatic, hydraulic (or electrical)
Pneumatic, hydraulic (or electrical)
Pneumatic, hydraulic (or electrical)
Pneumatic, hydraulic (or electrical)
Electrical or pneumatic
Electrical or pneumatic
Stack arrangement
Merged or seperate
Merged or seperate
Merged or seperate
Merged or seperate
Integral merged
Integral merged

   
Kanfa-Tec AS - Nye Vakås vei 80 - 1395 Asker - Norway - Tel: +47 64001800 - Fax: +47 64001801 - post@tec.no